Ensure consistent, reliable chemical analysis results with our premium Cellotetraose CAS 38819-01-1, a 99% purity ISO certified reference material designed to eliminate variability in critical testing workflows. This solid D-(+)-Cellotetraose delivers the precision industrial laboratories demand, supporting everything from quality control to advanced research with confidence in every batch.
- Stabilized for long-term reliability: Store at -20°C in dry conditions to maintain integrity, ensuring your reference material performs consistently over extended periods.
- Packaged in foil-alum bags or paper drums (250kg/drum or 1,250kg/IBC) to minimize degradation during transit and storage, addressing the need for secure, cost-effective bulk handling.
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Product Name | D-(+)-Cellotetraose |
| CAS Number | 38819-01-1 |
| Purity | 99% |
| Appearance | Solid |
| Melting Point | 251 °C (Decomp) |
| Boiling Point | 1116.9±65.0 °C |
| Acidity Coefficient | 12.39±0.20 |
| Storage Conditions | Long Term Storage -20 ℃, Dry |
| Transport Package | Foil-Alum Bag or Paper Drum |
| Specification | 250kg/drum Or 1,250kg/IBC |
| Origin | Hangzhou |
Cellotetraose CAS 38819-01-1: Overcoming Purity and Supply Challenges in Chemical Analysis
In chemical analysis and industrial R&D, inconsistent raw material quality can derail experiments—fluctuating purity levels cause irreproducible results, while delayed bulk deliveries disrupt project timelines. Over the past decade serving 10,000+ industrial clients, we’ve seen how substandard cellotetraose leads to costly rework and failed quality control checks.
Stabilizing Your Workflow with High-Purity Cellotetraose
Our Cellotetraose CAS 38819-01-1 addresses these pain points through ISO-certified production processes and a resilient supply chain. With a large warehousing center and kilogram-to-ton scale capabilities, we ensure consistent availability even for bulk orders, eliminating the production delays that plague research and manufacturing operations.
Industrial Applications of Cellotetraose
This solid cellotetraose serves as a critical reference material in chemical analysis, particularly in carbohydrate research, enzymatic studies, and quality control for cellulose-based product manufacturing. Its defined structure makes it invaluable for calibrating analytical instruments and validating testing methodologies in industrial laboratories.
Why Purity and Storage Matter for Reliable Results
The 99% purity of our cellotetraose minimizes interference from impurities, ensuring accurate quantification in HPLC and mass spectrometry analyses. Its stability under specified storage conditions (-20°C, dry environment) prevents degradation, maintaining batch consistency across long-term projects. The precise melting point (251°C decomp) provides a reliable identifier for authentication, while the tightly controlled acidity coefficient (12.39±0.20) ensures consistent behavior in solution-based applications.
Quality You Can Verify, Supply You Can Depend On
Choosing ISO-certified reference materials reduces the risk of non-compliance with industry standards, a critical factor for manufacturers serving regulated markets. Unlike uncertified products, our cellotetraose comes with traceable quality control data, helping you avoid the hidden costs of failed audits or product recalls. Our global supply chain ensures price stability even amid market fluctuations, supporting predictable budgeting for long-term research programs.
Our Commitment to Quality Assurance
Every batch of our cellotetraose undergoes rigorous testing, including NMR spectroscopy for structural confirmation and HPLC for purity assessment. We provide a Certificate of Analysis (COA) with each shipment, detailing batch-specific test results. Our production facility maintains ISO 9001 certification, and we offer a full replacement guarantee if any parameter fails to meet specifications. With dedicated technical support and a production capacity of 250kg per drum, we deliver both expertise and scalability for your projects.
Certificate of Analysis & Documentation
Each order includes a batch-specific COA and MSDS, with additional documentation available upon request. For critical applications, we can provide full analytical reports including NMR, HPLC, and elemental analysis data to support your quality control processes.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Ordering Process for Industrial Buyers
Our standard transaction process ensures efficiency: submit your procurement list for a bulk quotation, request a sample for evaluation, and finalize your order with flexible payment terms. We arrange secure sea or land transport and provide tracking information, with dedicated account managers available to coordinate delivery schedules that align with your production timeline.
Frequently Asked Questions
Q: What is the shelf life of your cellotetraose under proper storage conditions?
A: When stored at -20°C in a dry, sealed container, our cellotetraose maintains stability for 24 months from the date of manufacture.
Q: Is this product suitable for food, pharmaceutical, or medical applications?
A: No. This product is intended exclusively for industrial and laboratory research use and must not be used for human consumption, therapeutic, or household purposes.
Q: What documentation is provided with each shipment?
A: Each order includes a Certificate of Analysis (COA) with batch-specific test results and a Material Safety Data Sheet (MSDS).
Q: Do you offer custom packaging or alternative purity grades?
A: We can accommodate custom packaging requests for bulk orders. Contact our sales team to discuss specific requirements for your application.
Q: How is the purity of your cellotetraose verified?
A: Purity is determined by HPLC analysis with a validated method, ensuring compliance with ISO standards for reference materials.