FOR INDUSTRIAL AND LABORATORY RESEARCH USE ONLY. NOT FOR DIRECT HUMAN CONSUMPTION, THERAPEUTIC OR HOUSEHOLD USE.
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
| Product Name | Tricine |
| CAS Number | 5704-04-1 |
| Purity | >99% |
| Purity Degree | 99% |
| State | Solid |
| Molecular Formula | C6h13no5 |
| Boiling Point | 500.9±50.0 °c at 760 Mmhg |
| Melting Point | 186-188 °c (DEC.) |
| Packing | 25kgs |
| Transport Package | by Foil - Alum Bag or Paper Drum |
| Specification | 250kg/drum Or 1, 250kg/IBC |
| Origin | Hangzhou |
| HS Code | 2922509090 |
| Production Capacity | 20t/Year |
Overcoming Tricine 5704-04-1 Quality Instability in Industrial Processes
After 10+ years serving chemical production enterprises and research institutions worldwide, we’ve witnessed how inconsistent Tricine quality disrupts processes—from batch-to-batch purity fluctuations causing unexpected副反应 to delayed deliveries halting production lines. Researchers report that even 0.5% impurity variations in solid reference materials can invalidate months of analytical work, while manufacturers struggle with rising costs from material waste.
A Stable Supply Chain for Reliable Tricine Performance
Our Tricine CAS 5704-04-1 addresses these challenges through a vertically integrated supply chain. With a dedicated 20t/year production line in Hangzhou and strict in-process testing, we ensure each batch maintains >99% purity. As a comprehensive industrial chemical supplier serving 50+ countries, we offer flexible bulk quantities from kilogram to ton levels, eliminating the risks of supply interruptions that plague smaller distributors.
Industrial Applications of Tricine Reference Material
This high purity Tricine for analysis finds critical use in industrial chemical synthesis, where its consistent composition ensures reaction reproducibility. Laboratories utilize it as a solid reference material for calibration of analytical instruments and development of quality control protocols. Its stability makes it suitable for manufacturing processes requiring precise pH buffering and as an intermediate in specialty chemical production—all strictly within industrial and research contexts.
Key Specifications That Impact Your Process
The >99% purity of our Tricine minimizes interference from organic impurities, reducing side reactions in synthesis applications and ensuring accurate analytical results. Its defined melting point (186-188°C) allows for reliable thermal process control, while the solid state ensures easy handling and precise dosing compared to liquid alternatives. The standardized packaging—25kg foil-alum bags or 250kg drums—prevents moisture absorption during storage, maintaining stability from production to use. Each parameter is validated through rigorous testing to meet the stringent requirements of industrial scale production.
Quality Assurance: The Foundation of Process Reliability
Choosing substandard Tricine risks production delays, product recalls, and research inconsistencies. Our 99% purity Tricine reference material adheres to strict quality control standards, supported by batch-specific testing. As an ISO 9001-compliant supplier, we ensure each delivery meets international regulatory requirements, including proper documentation for cross-border shipments. The consistent quality translates to predictable process costs, reduced waste, and long-term supply stability—critical factors in today’s competitive chemical manufacturing landscape.
Our Commitment to Quality and Transparency
Every batch of Tricine 5704-04-1 undergoes comprehensive testing, including HPLC purity analysis and melting point verification, with results documented in a Certificate of Analysis (COA). Our production facility maintains full traceability from raw material sourcing to final packaging, and we provide MSDS documentation for safe handling. With 10,000+ satisfied industrial customers, we stand behind our product with a no-questions return policy if specifications are not met. Our technical team offers personalized support to help optimize your application and address specific process requirements.
Certificate of Analysis & Documentation
Each shipment includes a batch-specific COA with detailed purity testing results and compliance information. MSDS documents are provided for safe storage, handling, and disposal procedures. For critical applications, additional testing data can be requested, including impurity profiles and stability studies, to support your quality control processes and regulatory compliance needs.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Ordering Process for Industrial Buyers
To ensure your Tricine supply aligns with production schedules, we offer a straightforward procurement process: submit your required quantity and packaging specifications for a customized quote, request a sample for qualification testing, and place your order with flexible payment terms. We provide clear delivery timelines and proactive communication throughout the process, with support for both regular replenishment and urgent orders to keep your operations running smoothly.
Frequently Asked Questions
Q: What is the shelf life of your Tricine product?
A: When stored properly in sealed packaging under recommended conditions, our Tricine maintains specification for 24 months from the date of manufacture, as indicated on the COA.
Q: Is this Tricine suitable for pharmaceutical or food applications?
A: No. This product is supplied FOR INDUSTRIAL AND LABORATORY RESEARCH USE ONLY and is not intended for human consumption, therapeutic, or household applications.
Q: What documentation is provided with each order?
A: Every shipment includes a Certificate of Analysis (COA) with batch-specific testing data and a Material Safety Data Sheet (MSDS) for safe handling.
Q: Can you accommodate custom packaging or purity requirements?
A: We offer standard packaging options (25kg bags, 250kg drums, 1250kg IBCs) and can discuss custom solutions for large-volume orders. Our standard purity is >99%; please contact our technical team for specialized requirements.
Q: How do you ensure the purity of your Tricine?
A: Each batch undergoes HPLC analysis to verify purity >99%, with additional testing for melting point, moisture content, and residual solvents. Full testing records are maintained and available upon request.
Usage Notice: Supplied exclusively for industrial manufacturing and laboratory research purposes. The buyer is fully responsible for complying with all local laws, regulations and safety requirements for its use.